JAR 25B997 Fuel strainer or filter
There must be a fuel strainer or filter between
the fuel tank outlet and the inlet of either the fuel
metering device or an APU driven positive
displacement pump, whichever is nearer the fuel
tank outlet. This fuel strainer or filter must –
(a) Be accessible for draining and cleaning
and must incorporate a screen or element which is
easily removable;
(b) Have a sediment trap and drain except
that it need not have a drain if the strainer or filter
is easily removable for drain purposes;
(c) Be mounted so that its weight is not
supported by the connecting lines or by the inlet
or outlet connections of the strainer or filter itself;
and
(d) Have the capacity (with respect to
operating limitations established for the APU) and
the mesh to ensure that APU fuel system
functioning is not impaired, with the fuel
contaminated to a degree (with respect to particle
size and density) that is greater than that
established for the APU in JAR–APU, Section 1,
Appendix 1, paragraph 6.6.
|
JAR 25В997 Горивни цедки и филтри
Трябва да има горивна цедка или филтър между изходното отверстие на горивният резервоар и входа на устройството за измерване на разхода на гориво или входа на задвижвана от СЕА помпа с положителен дебит, което е по-близо разположено до изходния отвор на горивния резервоар. Горивната цедка или филтър трябва –
-
Да са достъпни за дрениране и почистване и трябва да включват мрежа или елемент, който е лесно сменяем.
-
Да имат утайник и дренаж, освен това те не е необходимо да имат дренаж, ако цедката или филтъра са лесно снемаеми за целите на дренирането.
-
Да са монтирани така, че тяхното тегло да не се поддържа от свързаните с тях тръбопроводи или от самите входни или изходни съединения на цедката или филтъра, и
-
Да имат обем (с отчитане на експлоатационните ограничения, установени за СЕА) и проходно отверстие, осигуряващо, че функционирането на горивната система на СЕА няма да се влоши, при замърсяване на горивото в степен (с отчитане на действителните размери и плътност на замърсяването) която е по-голяма от тази, установена за СЕА съгласно JAR-APU, Част 1, Приложение 1, параграф 6.6.
|
|
JAR 25B1011 General
(b) The usable oil capacity may not be less
than the product of the endurance of the aeroplane
under critical operating conditions and the
approved maximum allowable oil consumption of
the APU under the same conditions, plus a
suitable margin to ensure system circulation.
| МАЛЕНА СИСТЕМА
JAR 25В1011 Общи положения
-
Използваното количество масло не може да е по-малко отколкото е необходимо за осигуряване на продължителността на полета и утвърдената максимална допустима консумация на масло от СЕА плюс подходящ запас, за да се осигури циркулация на системата.
|
|
JAR 25B1091 Air intake
(b) For APUs –
(2) The aeroplane must be designed to
prevent water or slush on the runway, taxiway,
or other airport operating surfaces from being
directed into the APU air intake duct in
hazardous quantities, and the air intake duct
must be located or protected so as to minimise
the ingestion of foreign matter during take-off,
landing, and taxiing.
| СИСТЕМА НА ВХОДНОТО УСТРОЙСТВО ЗА ВЪЗДУХ
JAR 25В1091 Входно устройство за въздух
-
За СЕА -
-
Самолетът трябва да е проектиран така, че да се предотврати вода или киша от пистата, пътекит за рулиране или други летищни експлоатационни площи да попаднат директно в канала на входното устройство на СЕА в опасни количества и каналът на входното устройство на СЕА трябва е разположен и защитен така, че да минимизира засмукването на чужди предмети по време на излитане, кацане и рулиране.
|
|
JAR 25B1093 Air intake system de-icing
and anti-icing provisions
(b) (2) Each air intake system of an
essential APU must be such as to enable the
APU to operate throughout its flight power
range without adverse effect on its operation or
serious loss of power, under the icing
conditions specified in Appendix C (see ACJ
25B1093 (b)(2)).
|
JAR 25В1093 Предвиждания за отстраняване на лед и противообледеняване на входното устройство
-
(2) Всяко входно устройство за въздух към основен СЕА, трябва да е такава, че да позволи работата на СЕА през неговия полетен диапазон от мощности, без неблагоприятно въздействие върху неговата експлоатация или сериозна загуба на мощност, в условията на обледеняване, определени в Приложение С на JAR-25.
|
|
JAR 25B1105 Air intake system screens
(b) No screen may be in any part of the air
intake system that is the only passage through
which air can reach the APU unless it can be
shown that the screen does not ice up to an
unacceptable degree.
|
JAR 25В1105 Екрани на входното устройство за въздух
-
Не може да има екран в която и да е част от системата за подаване на въздух към СЕА, която е единствен път, през който въздухът може да достига СЕА, освен ако може да се демонстрира, че екранът не може да се обледени до неприемлива за работата на СЕА степен.
|
|
JAR 25B1163 APU accessories
(c) If continued rotation of an APU driven
cabin supercharger or of any remote accessory
driven by the APU is hazardous if malfunctioning
occurs, there must be means to prevent rotation
without interfering with the continued operation
of the APU.
| |